Related Experiment Video
Updated: Jan 29, 2026

Assessment of Motor Balance and Coordination in Mice using the Balance Beam
Published on: March 10, 2011
Assessment of haemophilic arthropathy through balance analysis: a promising tool
Xavier García-Massó1, Yiyao Ye-Lin2, Javier Garcia-Casado2
1a Departamento de Didáctica de la Expresión Musical Plástica y Corporal , Universidad de Valencia , Valencia , España.
The purpose of this study was to develop a tool able to distinguish between subjects who have haemophilic arthropathy in lower limbs and those who do not by analyzing the centre of pressure displacement. The second objective was to assess the possible different responses of haemophiliacs and healthy subjects by creating a classifier that could distinguish between both groups. Fifty-four haemophilic patients (28 with and 26 without arthropathy) and 23 healthy subjects took part voluntarily in the study. A force plate was used to measure postural stability. A total of 276 centre of pressure displacement parameters were calculated under different conditions: unipedal/bipedal balance with eyes open/closed. These parameters were used to design a Quadratic Discriminant Analysis classifier. The arthropathy versus non-arthropathy classifier had an overall accuracy of 97.5% when only 10 features were used in its design. Similarly, the haemophiliac versus non-haemophiliac classifier had an overall accuracy of 97.2% when only 7 features were used. In conclusion, an objective haemophilic arthropathy in lower limbs evaluation system was developed by analyzing centre of pressure displacement signals. The haemophiliac vs. non-haemophiliac classifier designed was also able to corroborate the existing differences in postural control between haemophilic patients (with and without arthropathy) and healthy subjects.
The purpose of this study was to develop a tool able to distinguish between subjects who have haemophilic arthropathy in lower limbs and those who do not by analyzing the centre of pressure displacement. The second objective was to assess the possible different responses of haemophiliacs and healthy subjects by creating a classifier that could distinguish between both groups. Fifty-four haemophilic patients (28 with and 26 without arthropathy) and 23 healthy subjects took part voluntarily in the study. A force plate was used to measure postural stability. A total of 276 centre of pressure displacement parameters were calculated under different conditions: unipedal/bipedal balance with eyes open/closed. These parameters were used to design a Quadratic Discriminant Analysis classifier. The arthropathy versus non-arthropathy classifier had an overall accuracy of 97.5% when only 10 features were used in its design. Similarly, the haemophiliac versus non-haemophiliac classifier had an overall accuracy of 97.2% when only 7 features were used. In conclusion, an objective haemophilic arthropathy in lower limbs evaluation system was developed by analyzing centre of pressure displacement signals. The haemophiliac vs. non-haemophiliac classifier designed was also able to corroborate the existing differences in postural control between haemophilic patients (with and without arthropathy) and healthy subjects.
Related Concept Videos
Balancing Redox Equations
Overview of Microsoft Excel as a Data Analysis Tool
Equilibrium and Balance
Energy Balance
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are...
Disorder of Water Balance
Dehydration
Dehydration occurs when the body loses fluids (particularly water).
Causes:
The major causes of dehydration include excessive sweating, fever, vomiting, diarrhea, and diuresis.
Signs and Symptoms:
Symptoms primarily include intense...

