Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
Published on: May 23, 2013
Is the Human Brain Capable of Controlling Seven Degrees of Freedom?
Frank Dewaele1, Tim De Pauw1, Alain Kalmar2
1Department of Neurosurgery, Ghent University Hospital, Ghent, Belgium.
Background:
Conventional rigid laparoscopic instruments offer five degrees of freedom (DOF). Robotic instruments add two independent DOFs allowing unconstrained directional steering. Several nonrobotic instruments have been developed with the additional DOFs, but with these devices, surgeon's wrist movements are not intuitively transmitted into tip movements. In this study, a new articulated instrument has been evaluated. The aim of the study was to compare learning curves and performances of conventional laparoscopic instruments, the da Vinci system and Steerable devices in a crossover study.
Materials And Methods:
A total of 16 medical students without any laparoscopic experience were trained for 27 h to operate all of a rigid, a robotic, and a new Steerable instrument in a random order. Learning curves and ultimate experience scores were determined for each instrument. Strain in wrist and shoulders was assessed with a visual analog score.
Results:
Performing the suturing task with rigid and robot instruments required 4 h of training, compared with 6 h to master the Steerable instrument. After 9 h of training with each instrument, completing the complex suturing pattern required 662 ± 308 s with rigid instruments, 279 ± 90 s with the da Vinci system, and 279 ± 53 s with the Steerable instrument. Pain scores were significantly higher after using the rigid instruments compared with the Steerable instruments.
Conclusions:
Transmission of torque and the presence of additional two DOFs in combination with reduced crosstalk significantly improved the instrument dexterity where the Steerable platform is concerned. Although the learning curve is longer, once mastered, it provides enhanced surgical freedom.
Related Concept Videos
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...
Degree of Unsaturation
The degree of unsaturation for hydrocarbons is U = (2C + 2 − H) / 2, where C is the number of carbon atoms and H is the number of hydrogen atoms.
Radian and Degree Measure
Degree of Curvature and Radius of Curvature