The effect of fluorescence on surface dose with superficial X-rays incident on tissue with underlying lead
John Baines1, S Zawlodzka2, T Markwell2
1Radiation Oncology Princess Alexandra Hospital, 31 Raymond Terrace, Brisbane, QLD, 4101, Australia. john.baines@health.qld.gov.au.
Abstract:
An Advanced Markus chamber on the surface of solid water phantom was used to determine surface dose reduction, with either a lead or air interface, as a function of surface-interface separation (t). The beam quality dependence of dose reduction was investigated using the 50 kV, 100 kV and 150 kV beams of an Xstrahl 150 superficial X-ray unit. For each beam the dose correction factor, DCF(t), namely the ratio of surface dose (t) to surface dose (t = 100 mm), was determined. Monte Carlo simulations of DCF(t) with a lead interface were compared with corresponding measured values. Simulated spectra were calculated at the phantom surface for full backscatter (t = 100 mm) and with either a lead or air interface at 2 mm or 8 mm depth. For each depth and beam quality lead fluorescent radiation at the surface was evident. The variation of DCF(t) for each beam and field size exhibits a minima at t ≈ 5 mm and in the range 1 mm ≤ t ≤ 40 mm surface dose reduction is larger for 100 kV than 150 kV. Monte Carlo simulated DCF(t) are consistent with corresponding measured DCF(t). From simulated spectra L-series fluorescent X-rays (≈ 15 keV) emanating from lead at t = 2 mm are evident for all beams and fluorescent K-series X-rays only occur with 100 kV and 150 kV beams.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
X-ray Imaging