Generic Neutravidin Biosensor for Simultaneous Multiplex Detection of MicroRNAs via Electrochemically Encoded

Sawsen Azzouzi1,2,3, Zina Fredj1,2,3, Anthony P F Turner1

  • 1Biosensors and Bioelectronics Centre, Department of Physics, Chemistry and Biology (IFM) , Linköping University , S-58183 Linköping , Sweden.

ACS Sensors
|February 8, 2019
PubMed

Related Concept Videos

MicroRNAs01:22

MicroRNAs

MicroRNA (miRNA) are short, regulatory RNA transcribed from introns—non-coding regions of a gene—or intergenic regions—stretches of DNA present between genes. Several processing steps are required to form biologically active, mature miRNA. The initial transcript, called primary miRNA (pri-mRNA), base-pairs with itself forming a stem-loop structure. Within the nucleus, an endonuclease enzyme, called Drosha, shortens the stem-loop structure into hairpin-shaped pre-miRNA. After...
24.2K
MicroRNAs01:22

MicroRNAs

MicroRNA (miRNA) are short, regulatory RNA transcribed from introns (non-coding regions of a gene) or intergenic regions (stretches of DNA present between genes). Several processing steps are required to form biologically active, mature miRNA. The initial transcript, called primary miRNA (pri-mRNA), base-pairs with itself, forming a stem-loop structure. Within the nucleus, an endonuclease enzyme, called Drosha, shortens the stem-loop structure into hairpin-shaped pre-miRNA. After the pre-miRNA...
4.0K
What is an Electrochemical Gradient?01:26

What is an Electrochemical Gradient?

Adenosine triphosphate, or ATP, is considered the primary energy source in cells. However, energy can also be stored in the electrochemical gradient of an ion across the plasma membrane, which is determined by two factors: its chemical and electrical gradients.
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
127.7K
Encoding01:19

Encoding

Information enters the brain through encoding, which is the input of information into the memory system. Once sensory information is received from the environment, the brain labels or codes it. The information is then organized with similar information and connected to existing concepts. Encoding occurs through automatic processing and effortful processing.
Automatic processing involves the encoding of details like time, space, frequency, and the meaning of words, usually done without conscious...
841
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules01:18

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules

Bioequivalence in generic drugs, such as tablets and capsules, refers to their pharmaceutical equivalence to the brand-name counterparts. However, for therapeutic equivalence, manufacturers must also consider physical attributes like size, shape, and weight (FDA Guidance for Industry, December 2003). Discrepancies in these aspects could impact patient compliance and cause medication errors. For instance, swallowing difficulties, often experienced with larger tablets or capsules, can lead to...
323
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
870