Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications
Published on: December 15, 2023
Deep neural networks assisted BOTDA for simultaneous temperature and strain measurement with enhanced accuracy
Abstract:
Simultaneous temperature and strain measurement with enhanced accuracy by using Deep Neural Networks (DNN) assisted Brillouin optical time domain analyzer (BOTDA) has been demonstrated. After trained by using combined ideal clean and noisy BGSs, the DNN is applied to extract both the temperature and strain directly from the measured double-peak BGS in large-effective-area fiber (LEAF). Both simulated and experimental data under different temperature and strain conditions have been used to verify the reliability of DNN-based simultaneous temperature and strain measurement, and demonstrate its advantages over BOTDA with the conventional equations solving method. Avoiding the small matrix determinant-induced large error, our DNN approach significantly improves the measurement accuracy. For a 24-km LEAF sensing fiber with a spatial resolution of 2m, the root mean square error (RMSE) and standard deviation (SD) of the measured temperature/strain by using DNN are improved to be 4.2°C/134.2με and 2.4°C/66.2με, respectively, which are much lower than the RMSE of 30.1°C/710.2με and SD of 19.4°C/529.1με for the conventional equations solving method. Moreover, the temperature and strain extraction by DNN from 600,000 BGSs along 24-km LEAF requires only 1.6s, which is much shorter than that of 5656.3s by the conventional equations solving method. The enhanced accuracy and fast processing speed make the DNN approach a practical way of achieving simultaneous temperature and strain measurement by the conventional BOTDA system without adding system complexity.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Measurements of Strain
Improving Translational Accuracy
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...

