A randomized trial evaluating the accuracy of AF detection by four external ambulatory ECG monitors compared to
Will Eysenck1, Nick Freemantle2, Neil Sulke3
1Eastbourne General Hospital, East Sussex Healthcare NHS Trust, East Sussex, UK. william.eysenck@nhs.net.
Purpose:
Several external cardiac monitors (ECMs) have recently been developed. These have never been compared to 'gold standard' monitoring with concurrently implanted DDDRP pacemakers. The accuracy of AF detection of Zio XT Monitor (ZM), NUUBO Vest (NV) and Carnation Ambulatory Monitor (CAM) compared with Novacor 'R' Test 4 (RT) in patients (pts) with DDDRP PPM advanced Holters as the comparator, was evaluated.
Methods:
Twenty-one pts. with AF and a DDDRP PPM, each acting as their own control subject, wore every ECM for 2 weeks in randomized order. PPM downloads were performed at application and removal. Device ECGs were compared for AF burden and individual AF episodes with PPM Holters. Pt acceptability, wear time, costs and time expenditure were evaluated.
Results:
RT AF burden was less accurate than the ZM, NV or CAM (p < 0.05). Probability of inaccurate AF diagnosis was higher for RT than ZM or CAM OR 12.31 and 5.85, respectively (p = 0.025 and p = 0.042). ZM wear time was longer than the RT: 307 h vs. 224 h; p = 0.02. Acceptability was greater for CAM than RT (1.86 ± 2.63 compared with 0.57 ± 1.17 for CAM; p = 0.024). All ECMs were more expensive than RT (p < 0.00001).
Conclusions:
All new ECMs were more expensive than the RT system; however, the ZM, NV and CAM are all more accurate than current standard practice RT device in AF burden assessment. The RT is more likely to give inaccurate diagnoses than ZM or CAM. This may have clinical implications.
More Related Videos
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Clinical Trials: Overview
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....