Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Simple geometrical modifications for substantial color intensity and detection limit enhancements in lateral-flow
Ali Zadehkafi1, Majid Siavashi2, Sasan Asiaei1
1Sensors and Integrated Bio-Microfluidics/MEMS Lab, School of Mechanical Engineering, Iran University of Science & Technology, Tehran, Iran.
Abstract:
One of the ongoing challenges in lateral flow Immunochromatographic assays (LFIA), is lowering the limit of detection and enhancing their signal quality, i.e. the color intensity. There are a number of rather costly and complicated processes for this aim, such as the use of functionalized materials/membranes and additional spectroscopic readout units. Nonetheless, there are simple and easy to practice alternatives, to be uncovered by analyzing the essential parameters of immunological reactions. The color intensity of the test line is a function of analytes flow velocity and their reaction rate. Detection pad width and test line position impact the flow velocity and reaction rate kinetics, examined in this paper for the limit of detection (LOD) and test-line color intensity. Firstly, the impact of width on the LOD was examined for human chorionic gonadotropin (pregnancy biomarker). Test line color intensity was measured using five different widths of the detection pad (trapezoidal) and four different test line positions, and the trends observed were explained according to the measured evolution of the velocity along the chromatography paper. With a constant width absorbent pad, LOD was cut by half to 5 mIU/ml by using a narrowing width detection pad, which keeps the wicking velocity higher than normal strips, and compared to them, color intensity increase between 55 and 150%, depending on the concentration. Nevertheless, a widening detection pad might cut the color intensity up to 150%, compared to normal strips, due to a profound decline of the analyte to ligand ratio at the test line. In addition, adequately sending the test line away from the conjugate pad yields the highest possible color intensity, for up to 400% of increase, in lower concentrations and narrowing test pads. However, further distancing the test line downfalls the color intensity.
More Related Videos
07:40Field Postmortem Rabies Rapid Immunochromatographic Diagnostic Test for Resource-Limited Settings with Further Molecular Applications
Published on: June 29, 2020
08:01Detection of Invasive Pulmonary Aspergillosis in Haematological Malignancy Patients by using Lateral-flow Technology
Published on: March 22, 2012
Related Concept Videos
Geometric Mean
In cases of multiplicative data, the geometric mean is used for statistical analysis. First, the product of all the elements is taken. Then, if there are n elements in the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Spreading of Chromatin Modifications
Writers
The writer...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Geometric Sequences
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...