Abstract:
We compared preoperative regular activity and low-activity radiology-based predictions with real surgical and pathological findings for parathyroidectomy surgery. The study retrospectively analyzed 54 consecutive cases (2009-2016) for benign tumor removal. Technetium-99m (Tc-99m)-sestamibi was used as a diagnostic radiopharmaceutical for diagnostic dual-phase parathyroid scintigraphy and single-photon emission computed tomography/computed tomography. We assessed images obtained with the radiation activity of 925 megabecquerel (MBq) and images obtained with the activity of 185 MBq. The study compared preoperative evaluation of tumor presence, multiplicity, location, and the type of pathology with actual data that were revealed during the operation and pathological investigation. The agreement between preoperative radiological prediction and actual location, number, and type of the parathyroid lesions was achieved in 98.4% (n = 61/62 lesions). The agreement between 925 MBq-based and 185-MBq based investigations was 100%. The agreement between radiological and pathological findings was 100% for both investigations. Our data suggest that the radioactivity of 185 MBq applied in the evaluation of the parathyroid glands provides results similar to the currently used 925-1110 MBq if used for diagnostic dual-phase parathyroid scintigraphy with Tc-99m-sestamibi. Such radioactivity may reduce the exposure to radiation of the patients and the staff without compromising results of the investigation.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Design Example: Traverse Angle Computations