Should spirometer quality control be treated like other laboratory devices?
Jeffrey M Haynes1, Gregg L Ruppel2
1Pulmonary Function Laboratory, St Joseph Hospital, Nashua, NH, USA.
ERJ Open Research
|February 19, 2019
Summary
The American Thoracic Society/European Respiratory Society spirometer calibration standards may be insufficient for ensuring accurate lung function testing. Further research is needed to validate current calibration protocols for reliable spirometry measurements.
Area of Science:
- Pulmonary Function Testing
- Respiratory Medicine
- Medical Device Calibration
Background:
- Spirometry is essential for diagnosing and managing respiratory diseases.
- Accurate spirometer calibration is critical for reliable test results.
- Current calibration standards are set by the American Thoracic Society (ATS) and European Respiratory Society (ERS).
Purpose of the Study:
- To evaluate the adequacy of existing ATS/ERS spirometer calibration standards.
- To identify potential limitations in current calibration protocols.
- To assess the impact of calibration variability on spirometry outcomes.
Main Methods:
- Review of current ATS/ERS spirometer calibration guidelines.
- Analysis of data from multiple spirometry devices and calibration procedures.
- Comparison of calibration results against established performance metrics.
Main Results:
- Findings suggest that current ATS/ERS calibration standards may not fully guarantee accuracy across all spirometers.
- Variability in calibration outcomes indicates potential for measurement error.
- Inadequacies in calibration could affect clinical decision-making.
Conclusions:
- The adequacy of ATS/ERS spirometer calibration standards requires further investigation.
- Refinement of calibration protocols may be necessary to improve spirometry accuracy.
- Ensuring robust calibration is vital for consistent and dependable pulmonary function testing.
Related Concept Videos
Quality Control
2.0K
Quality control is one of the three cyclical quality assurance activities that help keep a system under statistical control. Typical quality control activities include creating quality control charts, conducting proficiency testing, and documenting and archiving results.
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
2.0K
Quality Assurance
1.7K
Quality assurance is the overarching term used to describe the activities employed to ensure the proper performance of a system. These activities can be classified into three categories: quality control, quality assessment, and internal corrective measures. Typically, these activities work cyclically: quality control is performed before and during the analysis, while quality assessment occurs during and after the investigation. Internal corrective measures are implemented based on the findings...
1.7K
Quality of Water
556
In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
556
Pulse amplitude and quality
3.1K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
3.1K
Testing Water Quality
387
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
387
Non-ohmic Devices
1.5K
In most substances, the current flow is proportional to the voltage applied to it. A simple relationship between the values of current, voltage, and resistance is known as Ohm's law. Nonohmic devices do not exhibit a linear relationship between voltage and current. One such device is the semiconducting circuit element known as a diode. A diode is a circuit device that allows current flow in only one direction.
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
1.5K