Related Experiment Video
Updated: Jan 29, 2026

Study of Protein Dynamics via Neutron Spin Echo Spectroscopy
Published on: April 13, 2022
Comparison of 2D BLADE Turbo Gradient- and Spin-Echo and 2D Spin-Echo Echo-Planar Diffusion-Weighted Brain MRI at 3
Houchun H Hu1, Aaron S McAllister1, Ning Jin2
1Department of Radiology, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205.
Rationale And Objectives:
We describe our preliminary experience using a 2D turbo gradient- and spin-echo (TGSE) diffusion-weighted (DW) pulse sequence with non-Cartesian BLADE trajectory at 3 T in pediatric patients. We compared the TGSE BLADE to conventional DW spin-echo echo-planar imaging (SE-EPI) in pediatric brain imaging, assessing the presence of artifacts from signal pile-ups, geometric distortion, motion, susceptibility from air-tissue interface, shunts and orthodontia, and diagnostic image quality.
Materials And Methods:
Data were acquired in 53 patients (10.4 ± 7.9 years). All DW imaging data were acquired precontrast, with SE-EPI first. A four-point scale for rating was used-1 (best) and 4 (worst). A neuroradiologist scored the two sequences and further noted whether the TGSE BLADE approach or SE-EPI was preferred in each case. Apparent diffusion coefficients were compared quantitatively between the two sequences in a subset of 16 patients, in 41 separate regions of interests including caudate nucleus, putamen, globus pallidus, thalamus, and pathological areas.
Results:
In 43.4% of the cases, TGSE BLADE was preferred; in 49.1% of the cases, both sequences were preferred equally. Average scores for SE-EPI were 2.2 ± 0.8 versus TGSE's 1.2 ± 0.4 in assessing diagnostic quality (p < 0.05). Motion artifacts were minimal on both sequences in 92.5% of the cases. In the TGSE BLADE scores, no case received a "4" for significant artifacts with marginally acceptable image quality. Apparent diffusion coefficients values between the two sequences were statistically similar, with a linear regression slope of 0.92 (r2 = 0.97).
Conclusion:
TGSE BLADE DW imaging exhibited less geometric distortion in the brain and reduced signal pile-ups in areas of high susceptibility than conventional SE-EPI.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
NMR Spectroscopy: Spin–Spin Coupling
Spin–Spin Coupling: One-Bond Coupling
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...

