Hyphenation of short monolithic silica capillary column with vacuum ultraviolet spectroscopy detector for light
Huian Liu1, Guy Raffin1, Guillaume Trutt2
1Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France.
Abstract:
Compared to conventionnal bench top instruments, on-line GC analyzers require specific characteristics. On one hand, for some applications operating with a reactor pressure as high as several tens of bars, sample pressure has to be reduced before GC separation, or specific valves and columns have to be designed to perform separation with high carrier gas inlet pressure. On the other hand, informative detectors such as mass spectrometer are valuable but low maintenance detectors are prefered. To fit these two requirements (sampling at high pressure without decompression stage, and informative detector with low maintenance), short monolithic silica capillary column operated with inlet pressure as high as 60 bar has been hyphenated to VUV detector. Injection and column performance have been first investigated. The system has been optimized by adjusting split ratio at high pressure and by tuning two main VUV detector parameters ("average number" linked to data point averaging and make-up gas pressure) to decrease the limit of quantification. The optimization stage led to a set of experimental parameters which is a good compromise between signal-to-noise ratio and chromatographic efficiency. Finally, the hyphenated monolithic column has be used to partially separate a mixture of methane, ethane, carbon monoxide and carbon dioxide within 15 s, and the VUV deconvolution capabilities have been exploited to overcome coelution and finally separate individual signals.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
14:53Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...