Related Experiment Video
Updated: Jan 28, 2026

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Pre-hospital plasma in haemorrhagic shock management: current opinion and meta-analysis of randomized trials
Federico Coccolini1, Giacinto Pizzilli2, Davide Corbella3
11General, Emergency and Trauma Surgery, Bufalini Hospital, Viale Ghirotti 268, 47521 Cesena, Italy.
Background:
Trauma-induced coagulopathy is one of the most difficult issues to manage in severely injured patients. The plasma efficacy in treating haemorrhagic-shocked patients is well known. The debated issue is the timing at which it should be administered. Few evidences exist regarding the effects on mortality consequent to the use of plasma alone given in pre-hospital setting. Recently, two randomized trials reported interesting and discordant results. The present paper aims to analyse data from those two randomized trials in order to obtain more univocal results.
Methods:
A systematic review with meta-analysis of randomized controlled trials (RCTs) of pre-hospital plasma vs. usual care in patients with haemorrhagic shock.
Results:
Two high-quality RCTs have been included with 626 patients (295 in plasma and 331 in usual care arm). Twenty-four-hour mortality seems to be reduced in pre-hospital plasma group (RR = 0.69; 95% CI = 0.48-0.99). Pre-hospital plasma has no significant effect on 1-month mortality (RR = 0.86; 95% CI = 0.68-1.11) as on acute lung injury and on multi-organ failure rates (OR = 1.03; 95% CI = 0.71-1.50, and OR = 1.30; 95% CI = 0.92-1.86, respectively).
Conclusions:
Pre-hospital plasma infusion seems to reduce 24-h mortality in haemorrhagic shock patients. It does not seem to influence 1-month mortality, acute lung injury and multi-organ failure rates.Level of evidence: Level IStudy type: Systematic review with Meta-analysis.
Related Concept Videos
Hospitals-II
Nurses that work in...
Hospitals-I
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Statistical Software for Data Analysis and Clinical Trials
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...

