Related Experiment Video
Updated: Jan 28, 2026

Endotracheal Intubation in Mice via Direct Laryngoscopy Using an Otoscope
Published on: April 5, 2014
The Clarus Video System (Trachway) and direct laryngoscope for endotracheal intubation with cricoid pressure in
Yen-Chu Lin1, An-Hsun Cho1,2, Jr-Rung Lin1,3,4,2
1Department of Anesthesiology, Chang Gung Memorial Hospital, No.5, Fuxing St., Guishan Dist., Taoyuan City, 333, Taiwan.
Background:
During an emergency endotracheal intubation, rapid sequence induction intubation (RSII) with cricoid pressure (CP) is frequently implemented to prevent aspiration pneumonia. We evaluated the CVS in endotracheal intubation in RSII with CP, in comparison with a direct laryngoscope (DL).
Methods:
One hundred fifty patients were randomly assigned to one of three groups: the CVS as a video stylet (CVS-V) group, the CVS as a lightwand (CVS-L) group and DL group. Primary outcomes were to assess the power of the CVS, compared with DL, regarding the first attempt success rate and intubation time in simulated RSII with CP. Secondary outcomes were to examine hemodynamic stress response and the incidence of complications.
Results:
The first attempt success rates within 30 s and within 60 s were higher in CVS-V and DL group than those in CVS-L group (p = 0.006 and 0.037, respectively). The intergroup difference for intubation success rate within 30 s was nonsignificant and almost all the patients were successfully intubated within 60 s (98% for CVS-L and DL group, 96% for CVS-L group). Kaplan-Meier estimator demonstrated the median intubation time was 10.6 s [95% CI, 7.5 to 13.7] in CVS-V group, 14.6 s [95% CI, 11.1 to 18.0] in CVS-L group and 16.5 s [95% CI, 15.7 to 17.3] in DL group (p = 0.023 by the log-rank test). However, the difference was nonsignificant after Sidak's adjustment. The intergroup differences for hemodynamic stress response, sore throat and mucosa injury incidence were also nonsignificant.
Conclusions:
The CVS-D and DL provide a higher first attempt intubation success rate within 30 and 60 s in intubation with CP; the intubation time for the CVS-V was nonsignificantly shorter than that for the other two intubation methods. Almost all the patients can be successfully intubated with any of the three intubation methods within 60 s.
Trial Registration:
ClinicalTrials.gov identifier: NCT03841890 , registered on February 15, 2019 (retrospectively registered).
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Clinical Trials: Overview
Trial and Error and Algorithm
Clinical Trials
There are four phases in a clinical trial. A phase one...
Random Error

