Related Experiment Video
Updated: Jan 28, 2026

11:13
Porcine Model of Infrarenal Abdominal Aortic Aneurysm
Published on: November 21, 2019
9.8K
Correction to: Computational study on hemodynamic changes in patient-specific proximal neck angulation of abdominal
Yousif A Algabri1, Sorracha Rookkapan2, Vera Gramigna3
1Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, 6th floor, 100-year Building, Hatyai, Songkhla, 90110, Thailand.
Australasian Physical & Engineering Sciences in Medicine
|March 6, 2019
Abstract:
The name of the third author was incorrect in the initial online publication. The original article has been corrected.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
324
Thoracic, aortic arch and abdominal aneurysms are significant vascular conditions that can present with various clinical manifestations and lead to serious complications. Understanding these manifestations and the appropriate diagnostic studies is essential for effective management and treatment.Thoracic Aortic AneurysmsThoracic aortic aneurysms often remain asymptomatic until they reach a size that impinges on adjacent structures. They typically cause deep, diffuse chest pain that radiates to...
324
Distance Corrections
282
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
282
Gradually Varying Flow
429
Gradually varying flow (GVF) in open channels describes situations where water depth changes slowly along the channel due to factors like non-uniform bed slope, channel shape variations, or obstructions. This flow type occurs when the depth adjusts gradually to balance gravitational forces, shear forces, and energy requirements, resulting in a low rate of depth change.Characteristics of Gradually Varying FlowGVF is commonly observed in natural streams, rivers, and canals, where flow depth...
429
Rapidly Varying Flow
474
Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
474
Imaging Studies III: Computed Tomography
351
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
351
Power Factor Correction
528
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
528

