Related Experiment Video
Updated: Jan 28, 2026

IgY Technology: Extraction of Chicken Antibodies from Egg Yolk by Polyethylene Glycol PEG Precipitation
Published on: May 1, 2011
Efficacy of 1.2 L polyethylene glycol plus ascorbic acid for bowel preparations
Hiroyuki Tamaki1, Teruyo Noda1, Masahiro Morita1
1Department of Gastroenterology, Takamatsu Red Cross Hospital, Takamatsu, Kagawa 760-0017, Japan.
Background:
A low-volume polyethylene glycol (PEG) solution that combines ascorbic acid with PEG-based electrolyte solution (PEG-ASC) is gaining mainstream acceptance for bowel preparation due to reduced volume and improved taste. Although several reports showed that bowel preparation with PEG-ASC volume lower than 2.0 L with laxative agents could be an alternative to traditional preparation regimen, the cleansing protocols have not been fully investigated.
Aim:
To evaluate the cleansing efficacy of 1.2 L PEG-ASC solution comparing with 2.0 L PEG electrolyte (PEG-ELS) for bowel preparations.
Methods:
A randomized, single-blinded, open-label, single-center, non-inferiority study was conducted. In total, 312 Japanese adult patients (aged > 18 years) who underwent colonoscopy were enrolled. Patients were randomly allocated to bowel lavage with either 1.2 L of PEG-ASC solution with at least 0.6 L of an additional clear fluid (1.2 L PEG-ASC group) or 2.0 L of PEG-ELS (PEG-ELS group). Then, 48 mg of sennoside was administered at bedtime on the day before colonoscopy, and the designated drug solution was administered at the hospital on the day of colonoscopy. Bowel cleansing was evaluated using the Boston Bowel Preparation Scale (BBPS). The volume of fluid intake and required time for bowel preparation were evaluated. Furthermore, compliance, patient tolerance, and overall acceptability were evaluated using a patient questionnaire, which was assessed using a visual analog scale.
Results:
In total, 291 patients (1.2 L PEG-ASC group, 148; PEG-ELS group, 143) completed the study. There was no significant difference in successful cleansing, defined as a BBPS score ≥ 2 in each segment, between the two groups (1.2 L PEG-ASC group, 91.9%; PEG-ELS group, 90.2%; 95%CI: -0.03-0.09). The required time for bowel preparation was significantly shorter (164.95 min ± 68.95 min vs 202.16 min ± 68.69 min, P < 0.001) and the total fluid intake volume was significantly lower (2.23 L ± 0.55 L vs 2.47 L ± 0.56 L, P < 0.001) in the 1.2 L PEG-ASC group than in the PEG-ELS group. Palatability, acceptability of the volume of solution, and overall acceptability evaluated using a patient questionnaire, which was assessed by the visual analog scale, were significantly better in the 1.2 L PEG-ASC group than in the PEG-ELS group (7.70 cm ± 2.57 cm vs 5.80 cm ± 3.24 cm, P < 0.001). No severe adverse event was observed in each group.
Conclusion:
The 1.2 L PEG-ASC solution was non-inferior to the 2.0 L PEG-ELS solution in terms of cleansing efficacy and had better acceptability among Japanese patients.
More Related Videos
Related Concept Videos
Polyprotic Acids
Preparation of Acid Anhydrides
The carboxylate ion acts as a nucleophile that attacks the carbonyl carbon of the acid chloride to form a tetrahedral intermediate. Subsequently, the re-formation of the carbonyl group with the loss of the chloride ion as a leaving group leads to the formation of an acid...
Preparation of Carboxylic Acids: Overview
Self-Efficacy
Preparation of Carboxylic Acids: Hydrolysis of Nitriles
Preparation of Aldehydes and Ketones from Carboxylic Acid Derivatives
Carboxylic acid derivatives like acid chlorides and esters are more easily reducible than the corresponding acids. The derivatives reduce in the presence of mild reducing agents to give aldehydes. Aldehydes can also be prepared by Rosenmund reduction, that is, the reduction of...

