A randomized, controlled, clinical study on a new titanium oxide abutment surface for improved healing and soft
Jan Hall1, Jessica Neilands2, Julia R Davies2
1The Brånemark Clinic, Public Dental Health Service, Västra Götaland, Gothenburg, Sweden.
Background:
A newly developed, anodized titanium oxide surface containing anatase has been reported to have antimicrobial properties that could reduce bacterial adherence to abutments.
Purpose:
To investigate if abutments with the anodized surface improve healing and soft tissue health in a randomized controlled study.
Materials And Methods:
Test abutments with a nanostructured anodized surface were compared with control machined titanium abutments. In total, 35 subjects each received a pair of test and control abutments. The primary endpoint was reduction of biofilm formation at test abutments at the 6-week follow-up. Secondary endpoints included several soft tissue assessments. qPCR for gene markers was used to indirectly evaluate healing and soft tissue health.
Results:
No significant differences in biofilm formation were observed between test and control abutments, but soft tissue bleeding upon abutment removal was significantly lower for test abutments compared with control abutments (P = 0.006) at 6 weeks. Keratinized mucosa height was significantly greater at test abutments compared with control abutments at the 6-week, 6-month, and 2-year follow-ups. Significant gene expression differences indicated differences in healing and tissue remodeling.
Conclusions:
Abutments with an anodized and nanostructured surface compared with a conventional, machined titanium surface had no significant effect on bacterial colonization and proteolytic activity but were associated with better soft tissue outcomes such as a lower bleeding index at abutment removal and consistently greater height of keratinized mucosa throughout the 2-year follow-up, suggesting improved surface-dependent peri-implant healing and soft tissue health.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Oxidation Numbers
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization
Simple...