Related Experiment Video
Updated: Jan 27, 2026

12:34
Agar-Block Microcosms for Controlled Plant Tissue Decomposition by Aerobic Fungi
Published on: February 3, 2011
15.5K
Moisture Loss from Agar Plates During Incubation 1
1Department of Food Science & Nutrition, University of Missouri, Columbia, Missouri 65211.
Journal of Food Protection
|March 15, 2019
Summary
Incubator temperature significantly impacts agar weight loss during incubation. Other factors like media composition and humidity also play a role in evaporative losses.
Area of Science:
- Microbiology
- Laboratory Science
- Experimental Design
Background:
- Evaporative water loss from agar in Petri plates during incubation is a critical factor affecting experimental outcomes.
- Understanding variables influencing this loss is essential for reproducible microbiological studies.
Purpose of the Study:
- To identify and rank the importance of various factors contributing to evaporative weight loss of agar in Petri plates during incubation.
- To determine the primary driver of evaporative losses in microbiological incubators.
Main Methods:
- Systematic variation of incubation parameters including media composition, agar volume, relative humidity, shelf placement, and incubation time.
- Precise measurement of weight loss in Petri plates under controlled incubator conditions.
Main Results:
- Multiple variables were found to influence evaporative losses, including media composition, agar quantity, incubator humidity, and plate placement.
- Incubation temperature emerged as the most significant factor affecting the rate of evaporative weight loss.
Conclusions:
- Temperature is the paramount variable controlling evaporative weight loss of agar in Petri plates.
- Optimizing incubator temperature is crucial for minimizing variability and ensuring the reliability of microbiological assays.
Related Concept Videos
Line Loss
541
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
541
Moisture Content and Bulking of Aggregate
462
The moisture content of aggregates is a crucial factor in construction, particularly in concrete mixing, as it influences the total water required in the mix. Moisture content represents the water coated on the exterior surface of the aggregate existing in a saturated and surface-dry condition. The total water content of a moist aggregate is the sum of its moisture content and water absorption.
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
462
Reducing Line Loss
384
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
384
Major Losses in Pipes
2.0K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K
Minor Losses in Pipes
1.9K
In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.9K
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K

