Ovarian Cancer Detection Using Photoacoustic Flow Cytometry
Published on: January 17, 2020
Multispectral photoacoustic imaging for the detection of subclinical melanoma
Andrew J Sinnamon1, Madalyn G Neuwirth1, Yun Song1
1Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania.
Background:
Photoacoustic imaging (PAI) is a noninvasive technique for melanin detection within melanoma metastases. While ex vivo and early studies suggest promising clinical application, there are no standardized parameters for defining presence of melanoma metastases.
Methods:
Following flank/hindlimb melanoma induction in BRaf-PTEN transgenic mice, bilateral inguinal lymph nodes (LN) were imaged in vivo at 4 to 8 weeks using PAI. Fourteen diagnostic parameters for in vivo detection of LN metastases were compared using the receiver operating characteristic and area-under-the-curve (AUC). Limits of detectability were assessed in ex vivo and in vitro phantom studies.
Results:
Forty-nine LNs were imaged in 25 mice. Among metastatic LNs, tumor size ranged from scattered cells to 2.8 mm. The strongest predictor of LN metastasis was the ratio of peak 10% PA melanin signal in the LN compared with adjacent soft tissue (median 4.22 for positive LNs vs 1.07 for negative LNs, P < 0.0001). The AUC was 0.95 (95% CI, 0.90-1.00). In phantom studies, B16 tumor cells were detectable at a concentration of 10 to 25 cells/μL and at a tissue depth of 2.5-3 cm.
Conclusions:
We identified a simple, objective diagnostic parameter for identifying melanoma LN metastases in vivo. These findings may help inform the design of future clinical trials.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Imaging Studies VII: Vascular Imaging