Related Experiment Video
Updated: Jan 27, 2026

Design, Fabrication, and Experimental Characterization of Plasmonic Photoconductive Terahertz Emitters
Published on: July 8, 2013
Terahertz plasmonic detector controlled by phase asymmetry
Abstract:
We demonstrate that a phase difference between terahertz signals coupled to the gate and source and gate and drain terminals of a field effect transistor (a TeraFET) induces a plasmon-assisted DC current, which is dramatically enhanced in the vicinity of plasmonic resonances. We describe a TeraFET operation with identical radiation amplitudes at the source and drain antennas but with a phase-shift-induced asymmetry. In this regime, the TeraFET operates as a tunable resonant polarization-sensitive plasmonic spectrometer, operating in the sub-terahertz and terahertz ranges of frequencies. We also propose an effective scheme of a phase-sensitive homodyne detector operating in this phase-asymmetry mode, which allows for a dramatic enhancement of the response. These regimes can be implemented in different materials systems, including silicon. The p-diamond TeraFETs could support operation in the 200 to 600 GHz atmospheric windows, which is especially important for beyond 5G communication systems.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Membrane Asymmetry Regulating Transporters
Flippase
Eukaryotic flippases are type-IV P-type ATPases or P4-ATPases belonging to P-type ATPase family proteins that are membrane-bound pumps involved in the ATP-mediated transport of ions and molecules across the membrane. Flippases flip specific phospholipids from the outer to the inner leaflet of a membrane. All P4-ATPases have one...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...