Objective And Background:
The Risk Analysis Index (RAI) predicts 30-, 180-, and 365-day mortality based on variables constitutive of frailty. Initially validated, in a single-center Veteran hospital, we sought to improve model performance by recalibrating the RAI in a large, veteran surgical registry, and to externally validate it in both a national surgical registry and a cohort of surgical patients for whom RAI was measured prospectively before surgery.
Methods:
The RAI was recalibrated among development and confirmation samples within the Veterans Affairs Surgical Quality Improvement Program (VASQIP; 2010-2014; N = 480,731) including major, elective noncardiac surgery patients to create the revised RAI (RAI-rev), comparing discrimination and calibration. The model was tested externally in the American College of Surgeons National Surgical Quality Improvement Program dataset (NSQIP; 2005-2014; N = 1,391,785), and in a prospectively collected cohort from the Nebraska Western Iowa Health Care System VA (NWIHCS; N = 6,856).
Results:
Recalibrating the RAI significantly improved discrimination for 30-day [c = 0.84-0.86], 180-day [c = 0.81-0.84], and 365-day mortality [c = 0.78-0.82] (P < 0.001 for all) in VASQIP. The RAI-rev also had markedly better calibration (median absolute difference between observed and predicted 180-day mortality: decreased from 8.45% to 1.23%). RAI-rev was highly predictive of 30-day mortality (c = 0.87) in external validation with excellent calibration (median absolute difference between observed and predicted 30-day mortality: 0.6%). The discrimination was highly robust in men (c = 0.85) and women (c = 0.89). Discrimination also improved in the prospectively measured cohort from NWIHCS for 180-day mortality [c = 0.77 to 0.80] (P < 0.001).
Conclusions:
The RAI-rev has improved discrimination and calibration as a frailty-screening tool in surgical patients. It has robust external validity in men and women across a wide range of surgical settings and available for immediate implementation for risk assessment and counseling in preoperative patients.
Related Concept Videos
Reliability and Validity
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Overview of Microsoft Excel as a Data Analysis Tool
Relative Risk
External and Internal Respiration