Related Experiment Video
Updated: Jan 27, 2026

Substantiating Appropriate Motion Capture Techniques for the Assessment of Nordic Walking Gait and Posture in Older Adults
Published on: May 12, 2016
Full-body motion assessment: Concurrent validation of two body tracking depth sensors versus a gold standard system
Maria do Carmo Vilas-Boas1, Hugo Miguel Pereira Choupina1, Ana Patrícia Rocha2
1Institute for Systems Engineering and Computers - Technology and Science (INESC TEC), and Faculty of Engineering (FEUP), University of Porto, 4200-391 Porto, Portugal.
Abstract:
RGB-D cameras provide 3-D body joint data in a low-cost, portable and non-intrusive way, when compared with reference motion capture systems used in laboratory settings. In this contribution, we evaluate the validity of both Microsoft Kinect versions (v1 and v2) for motion analysis against a Qualisys system in a simultaneous protocol. Two different walking directions in relation to the Kinect (towards - WT, and away - WA) were explored. For each gait trial, measures related with all body parts were computed: velocity of all joints, distance between symmetrical joints, and angle at some joints. For each measure, we compared each Kinect version and Qualisys by obtaining the mean true error and mean absolute error, Pearson's correlation coefficient, and optical-to-depth ratio. Although both Kinect v1 and v2 and/or WT and WA data present similar accuracy for some measures, better results were achieved, overall, when using WT data provided by the Kinect v2, especially for velocity measures. Moreover, the velocity and distance presented better results than angle measures. Our results show that both Kinect versions can be an alternative to more expensive systems such as Qualisys, for obtaining distance and velocity measures as well as some angles metrics (namely the knee angles). This conclusion is important towards the off-lab non-intrusive assessment of motor function in different areas, including sports and healthcare.
Related Concept Videos
Equation of Motion for a Rigid Body
The combined moments generated about the center of mass of the object are equal to the rate of change of the angular momentum of the body. An external force, when applied at a different...
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...