Related Experiment Video
Updated: Jan 27, 2026

Crack Monitoring in Resonance Fatigue Testing of Welded Specimens Using Digital Image Correlation
Published on: September 29, 2019
Stress Intensity Factor of Semielliptical Surface Crack in Internally Pressurized Hollow Cylinder-A Comparison
Gabriel de C Coêlho1, Antonio A Silva2, Marco A Santos3
1Federal University of Campina Grande (UFCG), Campina Grande-PB 58429-140, Brazil. gabrielcastro_c90@hotmail.com.
Abstract:
The purpose of this research is to compare both British standard BS 7910 (2013) and American standard API 579/ASME FFS-1 (2016) stress intensity factor (SIF) solutions by considering a series of semielliptical surface cracks located in the external surface of a pressurized hollow cylinder in the axial direction. Finite element analysis was used as a comparison basis for both standards' SIF results. The solution from the British standard provided consistent results compared to Finite Element (FE) results for crack depth not much higher than half the thickness in the deepest and surface-breaking points. Above those limits, the British standard's solutions diverged quite a lot from the American standard, whose results followed FE values for every crack depth/thickness ratio tested with a maximum percentage difference of 1.83%.