Related Experiment Video
Updated: Jan 27, 2026

Determining 3D Flow Fields via Multi-camera Light Field Imaging
Published on: March 6, 2013
Multi-Cue-Based Circle Detection and Its Application to Robust Extrinsic Calibration of RGB-D Cameras
Young Chan Kwon1, Jae Won Jang2, Youngbae Hwang3
1Department of Electronics Engineering, Incheon National University, Incheon 22012, Korea. yckwon@inu.ac.kr.
Abstract:
RGB-Depth (RGB-D) cameras are widely used in computer vision and robotics applications such as 3D modeling and human⁻computer interaction. To capture 3D information of an object from different viewpoints simultaneously, we need to use multiple RGB-D cameras. To minimize costs, the cameras are often sparsely distributed without shared scene features. Due to the advantage of being visible from different viewpoints, spherical objects have been used for extrinsic calibration of widely-separated cameras. Assuming that the projected shape of the spherical object is circular, this paper presents a multi-cue-based method for detecting circular regions in a single color image. Experimental comparisons with existing methods show that our proposed method accurately detects spherical objects with cluttered backgrounds under different illumination conditions. The circle detection method is then applied to extrinsic calibration of multiple RGB-D cameras, for which we propose to use robust cost functions to reduce errors due to misdetected sphere centers. Through experiments, we show that the proposed method provides accurate calibration results in the presence of outliers and performs better than a least-squares-based method.
Related Concept Videos
The Extrinsic Apoptotic Pathway
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...
Non-Verbal Cues
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Mohr's Circle for Moments of Inertia: Problem Solving
Consider a rectangular beam. The moments of inertia of the beam about the x and y axis are 2.5(107) mm4 and 7.5(107) mm4, respectively. The product of inertia is 1.5(107) mm4. Determine the principal moments of inertia and the orientation of the major and...

