Related Experiment Video
Updated: Jan 26, 2026

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
Optimal Inframammary Fold Incision Length Based on Implant Volume for Breast Enlargement: A Cadaveric Study
Claude Muresan1, Meghan M Ford1, Eric W Anderson1
1Division of Plastic Surgery, General Surgery Department, University of Louisville, Louisville, Ky.
Abstract:
Purpose: Breast augmentation is the most commonly performed aesthetic operation in the Unites States annually. With the increasing popularity of gel implants, optimal incisional length for specific implant volumes becomes a factor to consider. Our study is the first, to date, to measure optimal incisional length for increasing Mentor smooth, round, moderate plus silicone implant volumes. Method: Three cadaver breasts were dissected in our anatomy laboratory. After dissection of a subpectoral pocket via an inframammary fold incision, time of implant insertion was measured for increasing volumes with the use of increasing incisional site lengths. Results: Values for increased incisions are as follows: 2.5-cm incision facilitated 100-cm3 implant (average time [AvgT] 76 seconds); 3-cm incision 100-cm3 implant (AvgT 32 seconds), 200 cm3 (AvgT 84.33 seconds); 3.5-cm incision 100-cm3 implant (AvgT 13.00 seconds), 200 cm3 (AvgT 22.00 seconds), 300 cm3 (AvgT 33.67 seconds); 4-cm incision 100-cm3 implant (AvgT 5.67 seconds), 200 cm3 (AvgT 11.33 seconds), 300 cm3 (AvgT 21.33 seconds), 400 cm3 (AvgT 26 seconds); 4.5-cm incision 100-cm3 implant (AvgT 5 seconds), 200 cm3 (AvgT 15.17 seconds), 300 cm3 (AvgT 19.67 seconds), 400 cm3 (AvgT 26 seconds), 500 cm3 (AvgT 39.67 seconds), 600 cm3 (AvgT 59.33 seconds), 700 cm3 (AvgT 78.67 seconds); 5-cm incision 100-cm3 implant (AvgT 1 second), 200 cm3 (AvgT 3.67 seconds), 300 cm3 (AvgT 8 seconds), 400 cm3 (AvgT 13 seconds), 500 cm3 (AvgT 19.33 seconds), 600 cm3 (AvgT 23.33 seconds), 700 cm3 (AvgT 28 seconds), 800 cm3 (AvgT 33 seconds). Conclusion: Based on our results, the optimal incision size for increasing Mentor smooth, round, moderate plus volumes is as follows: 2.5 cm for 100-cm3 implant, 3 cm for 200-cm3 implant, 3.5 cm for 300-cm3 implant, 4 cm for 400-cm3 implant, 4.5 cm for 500- to 700-cm3 implant, and 5 cm for 800-cm3 implant. This guideline can be used to provide the most aesthetic results without tissue compromise.
Related Concept Videos
Enlargement of the Plasma Membrane
Protein Folding
Protein Folding
Protein Structure Is Critical to Its Biological Function
Proteins perform a wide range of biological functions such as catalyzing chemical reactions, providing...
Molecular Chaperones and Protein Folding
The...
Molecular Chaperones and Protein Folding
Constant Volume Calorimetry

