Related Experiment Video
Updated: Jan 26, 2026

Culture Methods to Determine the Limit of Detection and Survival in Transport Media of Campylobacter Jejuni in Human Fecal Specimens
Published on: March 10, 2020
Establishment of a dual mode immunochromatographic assay for Campylobacter jejuni detection
Deyun He1, Zhengzong Wu2, Bo Cui2
1State Key Laboratory of Plant Physiology and Biochemistry, College of Biological Sciences, China Agricultural University, Beijing 100094, China.
Abstract:
Campylobacter jejuni (C. jejuni) is considered one of the most common cause of human gastroenteritis. Aiming to detect C. jejuni in food products rapidly and sensitively, a dual mode lateral flow assay, based on the peroxidase mimicking and surface enhanced Raman scattering (SERS) enhancement properties of platinum coated gold nanorods (AuNR@Pt), was developed in this study. Under color mode and SERS mode, the proposed assay showed good linear response in the range of 102-106 cfu/mL and 102-5 × 106 cfu/mL with limits of detection of 75 cfu/mL and 50 cfu/mL, respectively (S/N = 3). Furthermore, the reliability of the dual-readout lateral flow assay (LFA) was successfully demonstrated by the application on milk samples, in which the recoveries ranged from 89.33% to 107.62%. Overall, the immunochromatographic assay developed in this work is promising and has good chance to be employed for sensitive detection of C. jejuni in food products.
More Related Videos
05:34Author Spotlight: Development of an Enhanced Protocol for Rapid and Accurate Isolation of Campylobacter from Food Products
Published on: February 23, 2024
09:43Subtyping of Campylobacter jejuni ssp. doylei Isolates Using Mass Spectrometry-based PhyloProteomics MSPP
Published on: October 30, 2016
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
Modes of Standing Waves - I
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...