Performance of single skin masonry walls subjected to hydraulic loading
D M Herbert1, D R Gardner1, M Harbottle1
1Cardiff School of Engineering, Cardiff University, Queens Buildings, Cardiff, CF24 3AA UK.
Abstract:
Property owners are facing increasing threats from flooding and in response are likely to turn to products designed to waterproof or 'seal' the outside of the building in an effort to prevent the ingress of flood water. However, very limited research has been conducted on the effect of this sealing action and the consequent hydraulic load acting upon the structure of the building. The theoretical safe application of waterproofing products has been suggested to be between 0.6 and 1 m (published guidance suggests 0.9 m), although the experimental evidence supporting these suggestions is either absent or limited in nature. This paper presents the findings of an experimental programme that has examined the effect of out-of-plane hydrostatic loading on masonry walls typical of domestic or commercial buildings. The study, conducted at 1/6th scale using a geotechnical centrifuge considers wall panels constructed from a variety of masonry units (autoclaved aerated concrete block, brick and brick-block) bound together with two different types of mortar. The wall panels were subject to an axial load representative of 1 storey of loading and were simply supported on all 4 sides. The load-out-of-plane deflection response of the panels was captured by a 3D digital image correlation system, and the water level at failure was compared to that predicted from previous research and the established yield line analysis method with encouraging results. When partial material and load factors were taken into consideration the results illustrated that a safe sealing height of 0.9 m, as quoted in the literature, would generally be inappropriate, whilst the safe sealing height of 0.6 m was not suitable for every case investigated. This supports the need for a suitable approach for the calculation of water levels at failure rather than the use of fixed values given in published literature.
Related Concept Videos
Composite Masonry Walls
Masonry Cavity Walls
Maintaining a clean cavity during construction...
Masonry Loadbearing Walls
Masonry Curtain Walls
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Expansion and Contraction in Masonry Walls
To...