Cardiac conduction abnormalities associated with pacemaker implantation after transcatheter aortic valve replacement
Stephen Cresse1, Trevor Eisenberg1, Carlos Alfonso1,2
1University of Miami Miller School of Medicine, Miami, Florida.
Background:
Complete heart block is a known complication after transcatheter aortic valve replacement (TAVR), often requiring pacemaker implantation within 24 hours of the procedure. However, clinical markers for delayed progression to complete heart block after TAVR remain unclear.
Objectives:
We examined electrocardiographic data that may correlate with delayed progression to complete heart block and need for pacemaker.
Methods:
This is a single-center retrospective study of 608 patients who underwent TAVR between April 2008 and June 2017. We excluded 164 (27.0%) patients due to having a pacemaker before the procedure or expiring within 24 hours of the procedure (8, 1.3%). We excluded an additional 50 (8.2%) patients who received a pacemaker within 24 hours of the procedure. Electrocardiograms (EKGs) obtained after the procedure were compared to the preprocedural EKG to detect new changes.
Results:
Left bundle branch block, intraventricular conduction delay, left anterior fascicular block, and right bundle branch block were the most commonly seen conduction abnormalities after TAVR (25.1%, 10.9%, 7.5%, and 3.6%, respectively). Both left bundle branch block (odds ratio [OR] = 2.77 [95% confidence interval (CI): 1.24-6.22]) and right bundle branch block (OR = 13.2 [95% CI: 4.18-41.70]) carried an increased risk of pacemaker implantation after TAVR. Additionally, ΔPR greater than 40 ms from baseline also carried an increased risk of pacemaker implantation (OR = 3.53 [95% CI: 1.49-8.37]).
Conclusion:
Left bundle branch block, right bundle branch block, and ΔPR greater than 40 ms were all associated with delayed progression to complete heart block and need for pacemaker implantation after TAVR.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Abnormal Proliferation
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...