Modified Drop Tower Impact Tests for American Football Helmets
Published on: February 19, 2017
Particle analysis of shape factors according to American Society for Testing and Materials
Stefan Schroeder1, Steffen Braun1, Ulrike Mueller1
1Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Abstract:
Polyethylene wear is one of the major factors influencing the survivorship of joint replacements. Depending on the number, size and morphology of the polyethylene particles, biological responses of the periprosthetic soft tissue in terms of inflammatory processes can occur, leading to loosening of the implant. Various parameters are used to analyze wear particles, which are usually determined by examining scanning electron microscopy (SEM) images with a particle analysis program. In this study, three different software solutions for particle analysis (self-developed Particleanalyzer_HD, Leica QWin and ImageJ) were compared regarding particle number, size and morphology. These solutions were also compared to the American Society for Testing and Materials (ASTM) F1877-16 specifications regarding particle morphology. SEM image analysis revealed no differences for the equivalent circle diameter (p = 0.969). However, a significant difference was found for the aspect ratio between the Particleanalyzer_HD and the other two software solutions (p < 0.001) and between Leica QWin and the other two software solutions regarding the roundness (p < 0.001). Only the Particleanalyzer_HD showed an excellent agreement with the ASTM standard for both morphology parameters (intraclass correlation = 1.000). Only the Particleanalyzer_HD calculated the two morphology parameters according to the ASTM standard. A comparison of the particle morphology between different studies is barely possible, as different algorithms for particle analysis are used. It is strongly recommended that the calculation according to the ASTM standard is used to improve future comparability of findings from wear analysis studies. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 108B:225-233, 2020.
Related Concept Videos
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Molecular Shape and Polarity
VSEPR Theory and the Basic Shapes
Subatomic Particles
Electrolytes: van't Hoff Factor
The colligative properties of a solution depend only on the number, not on the identity, of solute species dissolved. The concentration terms in the equations for various colligative properties (freezing point depression, boiling point elevation, osmotic pressure) pertain to all solute species present in the solution. Nonelectrolytes dissolve physically without dissociation or any other accompanying process. Each molecule that dissolves yields one...
Molecular Shapes
Two regions of electron density in a diatomic...