Related Experiment Video
Updated: Jan 26, 2026

Implantation of an Isoproterenol Mini-Pump to Induce Heart Failure in Mice
Published on: October 3, 2019
Simultaneous explantation and implantation of intrathecal pumps: a case series
Objective:
Intrathecal drug delivery devices (IDDDs) are a mainstay in the treatment of spasticity and refractory pain. While these devices have been shown to greatly improve the quality of life for patients, they also have a high perioperative complication and failure rate. A major complication of IDDD implantation is infection. The current standard of care in the treatment of IDDD infection necessitates that the pump be explanted and the infection treated prior to implantation of a new IDDD. This process leads to long hospital stays, interruptions in optimal medical management, and a high risk for dangerous drug withdrawals. The authors describe a technique that allows for the explantation of the infected pump and implantation of a new pump concurrently, which they have named the "Turner Switch" technique in honor of its inventor.
Methods:
The authors conducted a retrospective analysis of cases of infected IDDDs in which patients underwent simultaneous explantation of the infected pump and implantation of a new pump. Demographics and clinical data were collected.
Results:
Data from a total of 17 patients (11 male, 6 female) who underwent simultaneous IDDD explantation and implantation to treat infections were analyzed from a 3-year period. No patients experienced infection of the newly implanted pump or catheter. Of the 17 patients, 14 (82.4%) had baclofen pumps to treat spasticity and 3 (17.6%) had fentanyl pumps to treat chronic pain. The median hospital stay was 7 days, with 16 of 17 (94.1%) patients able to be discharged home or to a facility with a level of care similar to their preoperative care. All patients ultimately experienced complete resolution of their initial infections. Five patients (29.4%) required a return to the operating room within the next 5 months (for repair of a CSF leak in 2 cases, for treatment of infection at the old pump site in 2 cases, and for treatment of a CSF leak compounded with infection in 1 case). No patient experienced infection of the newly implanted pump or catheter.
Conclusions:
IDDD infections represent a large portion of morbidity associated with these devices. The current standard of care for deep pump infections requires pump explantation and a course of antibiotics prior to reimplantation of the IDDD. The authors demonstrate the effectiveness of a procedure involving simultaneous explantation of an infected pump and implantation of a new pump on the contralateral side in the treatment of IDDD infections.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Resistors In Series
In a series circuit, the...
Series Resonance
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...

