HIGH TIBIAL OSTEOTOMY USING A LOCKING TITANIUM PLATE WITH OR WITHOUT AUTOGRAFTING
Hakan Sarman1, Cengiz Isik2, Mustafa Uslu3
1Private Ethica Incirli Hospital, Department of Orthopedics and Traumatology, Istanbul, Turkey.
Objective:
To postoperatively evaluate knee scores, radiological assessment results, deficit correction, patellar height change, bone healing time, and weight bearing time in patients undergoing high tibial osteotomy (HTO) with/without autologous iliac bone grafting.
Methods:
This retrospective examination of treated controls from a randomized controlled study included 63 knees of 58 patients aged 46-59 years who underwent HTO with locking open wedge osteotomy plates. The patients were divided into two groups: Group A, HTO with autologous iliac bone grafts (n = 31); and Group B, HTO without autologous iliac bone grafts (n = 32). Clinical and radiological data were evaluated prospectively at the preoperative consultation and again at 6, 9, and 12 weeks, 6 months, and 1 year after the surgery (and annually thereafter).
Results:
There were no significant intergroup differences in the radiological assessment, deficit correction, patellar height change, bone-healing time, and weight-bearing time at any time after surgery. The knee scores changed positively in both groups (p < 0.001).
Conclusions:
There was no difference in the results of patients undergoing HTO with open wedge osteotomy titanium locking plates with or without autografting, and comorbidities resulting from autografts were eliminated with the use of locking plates. .
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Fluid Pressure over Curved Plate of Constant Width
Steady, Laminar Flow Between Parallel Plates
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
