Related Experiment Video
Updated: Jan 26, 2026

Preparation of Drosophila Larval Samples for Gas Chromatography-Mass Spectrometry GC-MS-based Metabolomics
Published on: June 6, 2018
Evaluating Phthalate Contaminant Migration Using Thermal Desorption⁻Gas Chromatography⁻Mass Spectrometry (TD⁻GC⁻MS)
Yukihiro Ouchi1, Hiroyuki Yanagisawa2, Shigehiko Fujimaki3
1Consumer & Retail Service Division, SGS Japan Inc., YBP East Tower 12F, 134 Godo-cho, Hodogaya-ku, Yokohama 240-0005, Japan. Yukihiro.Ouchi@sgs.com.
Abstract:
This study describes a methodology for evaluating regulatory levels of phthalate contamination. By collecting experimental data on short-term phthalate migration using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS), the migration of di(2-ethylhexyl) phthalate (DEHP) from polyvinyl chloride (PVC) to polyethylene (PE) was found to be expressed by the Fickian approximation model, which was originally proposed for solid (PVC)/liquid (solvent) migration of phthalates. Consequently, good data correlation was obtained using the Fickian approximation model with a diffusion coefficient of 4.2 × 10-12 cm²/s for solid (PVC)/ solid (PE) migration of DEHP at 25 °C. Results showed that temporary contact with plasticized polymers under a normal, foreseeable condition may not pose an immediate risk of being contaminated by phthalates at regulatory levels. However, as phthalates are small organic molecules designed to be dispersed in a variety of polymers as plasticizers at a high compounding ratio, the risk of migration-related contamination can be high in comparison with other additives, especially under high temperatures. With these considerations in mind, the methodology for examining regulatory levels of phthalate contamination using TD-GC-MS has been successfully demonstrated from the viewpoint of its applicability to solid (PVC)/solid (PE) migration of phthalates.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume