Multicenter experience with the Evolution RL mechanical sheath for lead extraction using a stepwise approach: Safety,
Federico Migliore1, Martina Testolina1, Antonio Sagone2
1Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy.
Pacing and Clinical Electrophysiology : PACE
|April 19, 2019
Summary
This study shows the Evolution RL sheath is a safe and effective tool for lead extraction (LE). It achieved high success rates with few complications, improving patient outcomes in complex cases.
Area of Science:
- Cardiovascular Medicine
- Medical Devices
- Surgical Procedures
Background:
- Limited data exists on the safety and effectiveness of Cook Medical's Evolution RL sheath for lead extraction (LE).
- Previous studies lack detailed outcome data for this specific LE tool.
Observation:
- A total of 393 leads were extracted from 198 patients using the Evolution RL sheath and ancillary tools in a stepwise manner.
- Infection was the primary indication for lead extraction (63.1%).
- The Evolution Shortie RL sheath was used in all cases, with complete lead extraction achieved in 12.2% of cases. The Evolution RL sheath was used in 87.8%, and the SteadySheath Evolution in 44% for challenging cases.
Findings:
- Complete procedural success was 97%, clinical success was 99%, and lead removal with clinical success was 99.5%.
- One major complication (0.5%) and 10 minor complications (5%) were recorded.
- Mortality predictors included impaired renal function, extraction due to infection, and diabetes.
Implications:
- The Evolution RL bidirectional rotational mechanical sheath and ancillary tools, when used in a systematic stepwise approach, demonstrate effectiveness and safety for lead extraction.
- This approach offers a high success rate for lead extraction, even in cases with tenacious fibrosis.
- Understanding mortality predictors is crucial for patient management following lead extraction.
Keywords:
Evolution RL rotational sheathcardiovascular implantable electronic deviceinfectionmortalitytransvenous lead extractionMore Related Videos
Related Concept Videos
Extraction: Effects of pH
1.3K
Consider a neutral form of an amine, B, with a partition coefficient, K, in a liquid mixture containing organic and aqueous phases. The pH of the aqueous phase affects the charge on acidic and basic solutes, and the charged form is usually more soluble in the aqueous phase. Suppose the conjugate acid form of the amine is soluble only in the aqueous phase while the base form is soluble in both phases. Then the distribution coefficient, D, can be given as the ratio of amine concentration in the...
1.3K
The Evidence for Evolution
47.7K
Genetic variations accumulating within populations over generations give rise to biological evolution. Evolutionary changes can result in the formation of novel varieties and entire new species. These changes are responsible for the diverse forms of life inhabiting the planet. The evidence for evolution suggests that all living organisms descended from common ancestors.
47.7K
RL Circuits
3.0K
An RL circuit consists of a resistor and an inductor and may have a source of emf connected to it. The inductor in the circuit helps to prevent rapid changes in current, which can be helpful if a steady current is required but the external source has a fluctuating emf. Consider an open RL circuit connected to a source of constant emf. As soon as the circuit is closed, the current begins to increase at a rate that depends only on the value of the inductance in the circuit. The greater the...
3.0K
Convergent Evolution
31.6K
Evolution shapes the features of organisms over time, ensuring that they are suited for the environments in which they live. Sometimes, selection pressure leads to the rise of similar but unrelated adaptations in organisms with no recent common ancestors, a process known as convergent evolution.
31.6K
RL Circuit without Source
1.7K
When a DC source is suddenly disconnected from an RL (Resistor-Inductor) circuit, the circuit becomes source-free. Assuming the inductor has an initial current denoted as I0, the initial energy stored in the inductor can be determined.
Applying Kirchhoff's voltage law around the loop of the circuit and substituting the voltages across the inductor and resistor yields a first-order differential equation. A logarithmic equation is obtained by rearranging the terms in this equation,...
Applying Kirchhoff's voltage law around the loop of the circuit and substituting the voltages across the inductor and resistor yields a first-order differential equation. A logarithmic equation is obtained by rearranging the terms in this equation,...
1.7K
RL Circuit with Source
1.6K
When an RL (Resistor-Inductor) circuit is connected to a DC source, the complete response of the circuit can be divided into two parts: the transient response and the steady-state response.
The transient response of the circuit is its temporary reaction to the sudden application of the DC source. This response is characterized by a current that exponentially decays to zero as time approaches infinity. During this transitional period, the inductor behaves like a short circuit, causing the source...
The transient response of the circuit is its temporary reaction to the sudden application of the DC source. This response is characterized by a current that exponentially decays to zero as time approaches infinity. During this transitional period, the inductor behaves like a short circuit, causing the source...
1.6K