Evaluation of the MOSkin dosimeter for diagnostic X-ray CT beams
L Mendes Pereira1, H J Khoury2, M E A Andrade2
1University Hospital of Würzburg, Würzburg, Germany.
Abstract:
The aim of the present study was to evaluate the response of the MOSkin MOSFET dosimeter for X-ray diagnostic CT beams. Experiments were performed to investigate the sensitivity, energy dependence, reproducibility, fading and angular dependence of the dose response for the device. The dosimeter's performance was evaluated for the standard radiation qualities RQT 8, RQT 9 and RQT 10 in a metrology laboratory. In a CT scanner, the MOSkin was used to assess the air kerma profile and the dose profile in a phantom. The integral of the dose profile was compared to the CPMMA,100 measured with a pencil ionization chamber. The results showed that the MOSkin response was linear and reproducible with doses in the CT range. Energy dependence varied up to a factor of 1.19 among the tested X-ray energies. Angular dependence of the response was not greater than 7.8% within the angle range from 0 to 90 degrees. Signal fading within 3 min was negligible. Additionally, the MOSkin was able to accurately assess the air kerma profile and the integral of the dose profile in a CT scanner. The integral of the dose profile in a phantom was in agreement with the CPMMA,100. The presented results demonstrated the potential of the MOSkin for application in CT dosimetry.
Related Concept Videos
Radiological Investigation I: X-ray and CT
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Heart Failure IV: Classification and Diagnostic Evaluation
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation