Related Experiment Video
Updated: Jan 26, 2026

Measurement of Myocardial Lactate Production for Diagnosis of Coronary Microvascular Spasm
Published on: September 17, 2021
Slender distal radial five French coronary shockwave lithotripsy
Gregory A Sgueglia1, Gaetano Gioffrè1, Fabiana Piccioni1
1Division of Cardiology, Sant'Eugenio Hospital, Rome, Italy.
Abstract:
Despite technological evolution, percutaneous coronary interventions targeting coronary calcifications remain challenging and associated with high rates of complications and adverse outcomes. Over the years, rotational atherectomy has emerged as the reference treatment of calcified coronary artery lesions despite some inherent limitations. Also, rotational atherectomy typically requires relatively large guiding catheters which may unfavorably impact on the decision for transradial access, especially when radial artery is small, and consequently offset the relevant clinical benefits associated to transradial access. Recently, a new technology has been introduced in interventional practice to implement coronary lithotripsy. The device implements multiple small emitters enclosed in a coronary balloon creating sonic pressure waves to selectively fracture calcium within the plaque and favorably modify vessel compliance. Owing to its specific design, coronary shockwave lithotripsy could be used with small bore guiding catheters which may allow for straightforward transradial percutaneous treatment of calcified coronary lesions even in patients with a small radial artery. To illustrate this concept, we report the first experience of slender transradial coronary shockwave lithotripsy with a five French sheathless guiding catheter.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology

