Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Published on: February 23, 2017
SIMBIO-SYS/STC stereo camera calibration: Geometrical distortion
Emanuele Simioni1, Vania Da Deppo1, Cristina Re1
1INAF Astronomical Observatory of Padova, Vicolo dell'Osservatorio 5, 35122 Padova, Italy.
Abstract:
The STereo imaging Channel (STC) is the first push-frame stereo camera on board an European Space Agency (ESA) satellite, i.e., the ESA-Japan Aerospace eXploration Agency mission BepiColombo. It was launched in October 2018, and it will reach its target, Mercury, in 2025. The STC main aim is to provide the global three-dimensional reconstruction of the Mercury surface. STC, the stereo channel of spectrometer and imagers for Mercury Planetary Orbiter BepiColombo-Integrated Observatory System, is based on an original optical design that incorporates the advantages of a compact unique detector instrument and the convenience of a double direction acquisition system. In fact, STC operates in a push-frame imaging mode and its two optical sub-channels will converge the incoming light on a single focal plane assembly allowing to minimize mass and volume. The focal plane of the instrument is housing six different filters: two panchromatic filters in the range 600-800 nm and four broadband filters with central wavelengths in the range 420-920 nm. In this paper, the geometrical calibration of the instrument, including the optical setups used, will be described. The methods used to derive the focal lengths, the boresights, and the reference systems of the different filter models are presented, and the related distortion results are discussed. The STC off-axis configuration forced to develop a distortion map model based on the RFM (rational function model). In contrast to other existing models, which allow linear estimates, the RFM is not referred to specific lens geometry, but it is sufficiently general to model a variety of distortion types, as it will be demonstrated in this particular case.
More Related Videos
Related Concept Videos
Geometric Mean
In cases of multiplicative data, the geometric mean is used for statistical analysis. First, the product of all the elements is taken. Then, if there are n elements in the...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Correlation Coefficient