Influence of voltage rise time on operation frequency in magnetically insulated transmission line oscillator

Yuwei Fan1, Sirui Li1, Xiaoyu Wang1

  • 1College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China.

Related Concept Videos

Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
559
Conductors and Insulators01:19

Conductors and Insulators

Some materials may easily let electrical charges pass through them, while others obstruct their flow. The former are called conductors and the latter insulators. The atomic structures of materials determine whether they are conductors or insulators of electricity.
Most metals are conductors. Their atomic configuration is such that one or more electron(s) are loosely bound to the nucleus in each atom. Thus, a sea of mobile electrons are available in them, known as free electrons. Their easy...
10.6K
Rise of Liquid in a Capillary Tube01:18

Rise of Liquid in a Capillary Tube

When very thin cylindrical tubes, called capillaries, are dipped in a liquid, the liquid rises or falls in the tube compared to the surrounding liquid. This phenomenon is called capillary action. Capillary action occurs due to the combination of two opposing forces: the cohesive forces of the liquid, which cause it to stick to itself and form a rounded shape, and the adhesive forces between the liquid and the walls of the container, which cause the liquid to be attracted to the container walls.
3.2K
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
405
Frequency-dependent Selection01:21

Frequency-dependent Selection

When the fitness of a trait is influenced by how common it is (i.e., its frequency) relative to different traits within a population, this is referred to as frequency-dependent selection. Frequency-dependent selection may occur between species or within a single species. This type of selection can either be positive—with more common phenotypes having higher fitness—or negative, with rarer phenotypes conferring increased fitness.
23.3K
Thermal Insulation in Masonry Walls01:22

Thermal Insulation in Masonry Walls

In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
518