Related Experiment Video
Updated: Jan 25, 2026

Detection of Live Escherichia coli O157:H7 Cells by PMA-qPCR
Published on: February 1, 2014
A Colorimetric DNA Hybridization Method for the Detection of Escherichia coli in Foods
Hsien-Yeh Hsu1, Samuel W Chan1, David I Sobell1
1GENE-TRAK Systems, 31 New York Avenue, Framingham, Massachusetts 01701.
Abstract:
A colorimetric DNA hybridization assay has been developed for the rapid detection of Escherichia coli in foods. The method employs two oligonucleotide probes which are specific for the 16S ribosomal RNA of E. coli . Probes are added to lysates of test cultures and allowed to hybridize to target rRNA if present. The probe-target complex is captured via hybridization to a polystyrene dipstick. The immobilized target is detected using an antibody-horseradish peroxidase conjugate which binds to the immobilized probe-target complex. The probe-target-antibody complex generates a colorimetric signal when exposed to a substrate/chromogen mixture. A total of 233 E. coli isolates representing typical, toxigenic, invasive, hemorrhagic serotype 0157:H7, and other pathogenic strains all resulted in a positive assay signal. Dose-response experiments indicate the sensitivity of the assay is approximately 1 × 106 CFU/ml. Specificity of the assay was determined by testing 207 strains of non- E. coli species at 109 CFU/ml. All of the non- E. coli organisms tested were negative with the exception of Escherichia fergusonii and Shigella species. A total of 345 enriched samples including inoculated, uninoculated, and naturally-contaminated foods was tested for the presence of E. coli by the hybridization assay and a conventional cultural method. The false-negative rate for the hybridization assay was 1.2%. By comparison, the false-negative rate for the culture method in these studies was 23.4%. Based on these data, the DNA hybridization method is significantly more accurate than conventional methods for the detection of E. coli in foods.
More Related Videos
12:50Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water
Published on: June 9, 2014
14:12Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Related Concept Videos
Hybrid Zones
Hybridization of Atomic Orbitals I
Hybridization of Atomic Orbitals II
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Regulation of Food Intake
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...