Related Experiment Video
Updated: Jan 25, 2026

Combining QD-FRET and Microfluidics to Monitor DNA Nanocomplex Self-Assembly in Real-Time
Published on: August 26, 2009
Visual detection of mixed organophosphorous pesticide using QD-AChE aerogel based microfluidic arrays sensor
1School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
Abstract:
In this paper, we present a simple strategy to fabricate a sensitive fluorescence microfluidic sensor based on quantum dots (QDs) aerogel and acetylcholinesterase enzyme (AChE) for organophosphate pesticides (OPs) detection The detection is based on the change of fluorescence intensity of QDs aerogel, which will be partly quenched as a consequence of the hydrolytic reaction of acetylthiocholine (ATCh) catalyzed by the AChE, and then the fluorescence of QDs aerogel is recovered due to decreasing of the enzymatic activity in the presence of OPs. The QDs-AChE aerogel based microfluidic arrays sensor provided good sensitivity for rapid detection of OPs with a detection limit of 0.38 pM, while the detection range is from 10-5 to 10-12 M. Due to the result of random orientations of AChE in the 3D porous aerogel nano-structure, the sensor presents similar calibration curves to difference pesticides, which promises the ability of the sensor to monitor total OPs of mixture. This determination sensor shows a low detection limit, wide linear range, and highly accurate determination of total OPs and carbamate content. Finally, we show the proposed sensor can be used to monitor of simple OPs and mixture in spiked fruit samples. This novel QDs-AChE aerogel sensor has an extremely high sensitivity and large detection range, it is a promising tool for accurate, rapid and cost-effective detection of various OP residues on agricultural products.
Related Concept Videos
Mixing Concrete
Mixing Time
Ready Mixed Concrete
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Adrenergic Agonists: Mixed-Action Agents
Ephedrine and pseudoephedrine lack a catecholamine group, making them less susceptible to degradation by metabolic enzymes. They have increased oral bioavailability and lipophilicity, resulting in a longer duration of action. Their response is reduced by...
Visual System
Once through the pupil, the light passes through the lens, a...

