Predicting Obstructive Sleep Apnea in Patients with Insomnia: A Comparative Study with Four Screening Instruments
Ricardo L M Duarte1,2, Flavio J Magalhães-da-Silveira3, Tiago S Oliveira-E-Sá4,5
1Centro Médico BarraShopping, Sleep - Laboratório de Estudo Dos Distúrbios Do Sono, Avenida das Américas 4666, sala 309, Barra da Tijuca, Rio de Janeiro, 22649-900, Brazil. rlmduarte@gmail.com.
No-Apnea, STOP-Bang, and NoSAS effectively screen for obstructive sleep apnea (OSA) in patients with insomnia. These tools show similar performance across all OSA severity levels, unlike the Epworth Sleepiness Scale (ESS).
Area of Science:
- Sleep Medicine
- Respiratory Medicine
- Diagnostic Tools
Background:
- Obstructive sleep apnea (OSA) and insomnia are highly prevalent, with insomnia often presenting as the primary complaint for OSA.
- Effective screening tools are crucial for identifying OSA in patients presenting with insomnia symptoms.
Purpose of the Study:
- To validate the No-Apnea screening tool for obstructive sleep apnea (OSA) in patients reporting insomnia.
- To compare the performance of No-Apnea against other established screening models like STOP-Bang, NoSAS, and the Epworth Sleepiness Scale (ESS).
Main Methods:
- A cross-sectional study evaluated No-Apnea, STOP-Bang, NoSAS, and ESS in 2591 patients with insomnia undergoing polysomnography.
- Discrimination was assessed using the area under the curve (AUC), with OSA severity categorized by the apnea/hypopnea index (≥5, ≥15, ≥30 events/h).
Main Results:
- No-Apnea demonstrated high sensitivity (84.5-94.1%) and moderate specificity (35.1-58.2%) across all OSA severity levels.
- The discriminatory ability (AUC) for No-Apnea ranged from 0.753 to 0.790.
- No-Apnea, STOP-Bang, and NoSAS showed comparable and satisfactory discrimination for OSA screening, while ESS performed poorly.
Conclusions:
- No-Apnea, STOP-Bang, and NoSAS are validated as effective screening tools for obstructive sleep apnea (OSA) in individuals with insomnia complaints.
- These tools provide satisfactory and similar discriminatory performance across all OSA severity levels.
- The Epworth Sleepiness Scale (ESS) is not recommended as a primary screening tool for OSA in this patient population.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Insomnia
Multiple factors contribute...
Management of Insomnia
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Instrument Transformers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...