Comparison of ultimate force revealed by compression tests on extracted first premolars and FEA with a true scale 3D
Nuttapol Limjeerajarus1, Phetcharat Dhammayannarangsi1, Anon Phanijjiva1
1Research Center for Advanced Energy Technology, Faculty of Engineering, Thai-Nichi Institute of Technology, Bangkok, 10250, Thailand.
Objective:
The aim of this study was to develop a new method for creating a multi-component and true scale 3-dimensional (3D) model of a human tooth based on cone-beam computed tomography (CBCT) images.
Materials And Methods:
First maxillary premolar tooth model was reconstructed from a patient's CBCT images. The 2D serial sections were used to create the 3D model. This model was used for finite element analysis (FEA). Model validation was performed by comparing the ultimate compressive force (UF) obtained experimentally using a universal testing machine and from simulation. The simulations of three component-omitting models (silicone, cementum, and omitting both) were performed to analyze the maximum (max.) principal stress and stress distribution.
Results:
The simulation-based UF indicating tooth fracture was 637 N, while the average UF in the in vitro loading was 651 N. The discrepancy between the simulation-based UF and the experimental UF was 2.2%. From the simulation, the silicone-omitting models showed a significant change in max. principal stress, resulting in a UF error of 26%, whereas there was no notable change in the cementum-omitting model.
Conclusion:
This study, for the first time, developed a true scale multi-component 3D model from CBCT for predicting stress distribution in a human tooth.
Clinical Relevance:
This study proposed a method to create 3D modeling from CBCT in a true scale and multi-component manner. The PDL-like component-omitting simulation led to a higher error value of UF, indicating the importance of multi-component tooth modeling in FEA. Tooth 3D modeling could help determine mechanical failure in dental treatments in a more precise manner.
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
True Stress and True Strain
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...
Molecular Comparison of Gases, Liquids, and Solids
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Tooth Anatomy
The Crown, Neck, and Root
The visible part of the tooth is referred to as the crown. It's covered by enamel, the hardest substance in the human body. The crown is uniquely shaped for each type of tooth, allowing for different functions such as cutting, tearing, or...