Image quality comparison between model-based iterative reconstruction and adaptive statistical iterative
Sandra Lin1, Monica Lin2, Kenneth K Lau2,3
1Austin Health, Melbourne, Victoria, Australia.
Introduction:
Cystic fibrosis (CF) predominantly affects young adults. Accurate radiological assessment of pulmonary disease is vital for predicting exacerbations, one of the leading causes of morbidity and mortality. We evaluated the image quality of model-based iterative reconstruction (MBIR) ultra-low-dose CT chest (ULD-CT) in CF evaluation.
Methods:
We compared ULD-CT with standard adaptive statistical iterative reconstruction (ASIR) low-dose CT (LD-CT). Subjective assessment of contrast and noise were performed for each study. Background noise, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated and compared between the CT studies. Conspicuity of major structures was assessed. These aspects of image quality were compared to determine whether ULD-CT was superior to LD-CT in assessment of CF.
Results:
The ULD-CT achieved median effective dose of 0.073 mSv, comparable to one standard chest radiograph and significantly lower than the median LD-CT dose of 1.22 mSv. ULD-CT had lower subjective contrast and higher subjective noise when compared to LD-CT. Objectively measured background noise was lower in ULD-CT (16.33 HU vs 38.53 HU, P < 0.0001) compared to LD-CT. ULD-CT had higher median CNR (52.65 vs 22.09, P < 0.0001) and SNR in lung (9.08 vs 7.29, P = 0.002) compared to LD-CT. ULD-CT was equal to LD-CT in identification of trachea, bronchi, pleural and pericardium. Interobserver reliability showed agreement of 80-92%.
Conclusions:
The image quality of ULD-CT is similar to LD-CT, at 1/16th the dose. MBIR constructed ULD-CT is an effective imaging modality for CF surveillance, with potential applications in other disease settings.
More Related Videos
07:58Computational Reconstruction of Pancreatic Islets as a Tool for Structural and Functional Analysis
Published on: March 9, 2022
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Cystic Fibrosis: Pathogenesis
CF is primarily caused by a genetic mutation in a chromosome 7 gene coding for the cystic fibrosis transmembrane conductance regulator (CFTR) protein. The most common gene mutation leading to CF is the ΔF508 mutation,...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Cystic Fibrosis: Management
Sinus disease and chronic...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Reconstruction of Signal using Interpolation