Whole-brain microcirculation detection after ischemic stroke based on swept-source optical coherence tomography
Jian Liu1, Ning Ding2, Yao Yu1
1School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China.
This study monitored whole-brain microcirculation in rats with middle cerebral artery occlusion (MCAO) using swept-source OCT. Real-time cerebral perfusion tracking offers new insights into ischemic stroke mechanisms and treatment assessment.
Area of Science:
- Neuroscience
- Biomedical Engineering
- Medical Imaging
Background:
- Ischemic stroke is linked to cerebral blood flow, making real-time perfusion monitoring crucial for understanding disease mechanisms.
- A wide field of view (FOV) is beneficial for capturing lesions and observing disease progression in stroke research.
Purpose of the Study:
- To monitor whole-brain microcirculation in middle cerebral artery occlusion (MCAO) rat models over time using a wide FOV swept-source OCT (SS-OCT) system.
- To quantify and compare cerebral perfusion levels in both hemispheres and the whole brain during ischemic conditions.
Main Methods:
- Utilized a wide FOV swept-source OCT (SS-OCT) system for whole-brain microcirculation monitoring in MCAO rats.
- Employed a constrained image registration algorithm to mitigate motion artifacts in wide FOV angiography.
- Quantified cerebral perfusion levels and recorded changes in blood vessel shape and location during ischemia.
Main Results:
- Demonstrated highly consistent trends in cerebral perfusion levels between the left and right hemispheres during MCAO.
- Observed temporal variations in the position of blood vessels throughout the experiment.
- Successfully quantified and compared perfusion across different brain regions.
Conclusions:
- Real-time, wide FOV SS-OCT monitoring provides valuable insights into whole-brain microcirculation dynamics during ischemic stroke.
- The findings support the utility of this technique for understanding stroke mechanisms and evaluating potential therapeutic interventions.
More Related Videos
03:47Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
Related Concept Videos
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
Source Transformation
It is essential to note that when...
AC Sources
Sources of Law
Constitutional law is foundational, deriving from federal and state constitutions, and...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...