Choriocapillary Blood Flow in Myopic Subjects Measured With OCT Angiography
Background And Objective:
To investigate choriocapillary blood flow in myopic eyes using optical coherence tomography angiography.
Patients And Methods:
Seventy-eight myopic and 79 age-matched healthy eyes were included in this study, with myopia defined as a spherical equivalent refraction (SER) between -1 diopters (D) and -6 D. Quantitative measurements of the choriocapillaris were obtained using the Avanti RTVue XR with AngioVue. Choroidal thickness (CT) was assessed using the single-line enhanced high-definition scan of the same device.
Results:
CT correlated positively with SER (P = .017) and negatively with bulbus axial length (AL) (P = .180). Subfoveal choriocapillary blood flow did not show any significant correlation with any of the parameters SER, AL, or CT (P = .798, P = .269, and P = .820, respectively). The mean flow signal of the myopic group did not differ significantly from the mean flow signal of the emmetropic control group (P = .266).
Conclusion:
Choriocapillary blood flow seems to retain a constant level with increasing physiological myopia. [Ophthalmic Surg Lasers Imaging Retina. 2019;50:e133-e139.].
Related Concept Videos
Blood Flow
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.