Related Experiment Video
Updated: Jan 24, 2026

Group Synchronization During Collaborative Drawing Using Functional Near-Infrared Spectroscopy
Published on: August 5, 2022
Simultaneous determination of metolazone and losartan in their combined tablets using synchronous fluorescence
Mona E Fathy1, Mohamed I El-Awady1, Fathalla Belal1
1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt.
Abstract:
Synchronous spectrofluorimetry is utilized to carry out a rapid, sensitive and reliable method for determination of the binary mixture of metolazone (MTL) and losartan potassium (LSP). Under optimized experimental conditions, the synchronized fluorescence spectra of the two drugs were measured at Δλ = 80 nm in acidic methanolic solution and intensities were recorded at 260 nm for MTL and 335 nm for LSP. Linear correlation between fluorescence intensity and concentration were obtained through the ranges 0.02-0.2 μg/mL and 0.2-2.0 μg/mL for MTL and LSP, respectively. Limits of detection were 3.02 and 0.12 ng/mL, whereas limits of quantification were 9.16 and 0.35 ng/mL for MTL and LSP, respectively. The designated procedure was easily and successfully adopted to determine the two compounds in their single, as well as in co-formulated, tablets and the results showed high precision and accuracy without any significant interference from common tablet excipients. A comparison of the obtained results with a published reference method was carried out and both showed good agreement with respect to accuracy and precision.
Related Concept Videos
Atomic Fluorescence Spectroscopy
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...

