Related Experiment Video
Updated: Jan 24, 2026

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Lubricating conditions: effects on friction between orthodontic brackets and archwires with different cross-sections
Fabrício Anderson Carvalho Almeida1, Anna Paula Costa Ponte Sousa Carvalho Almeida2, Flávia Lucisano Botelho Amaral3
1Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Divisão de Ortodontia (Campinas/SP, Brazil).
Objective:
This study investigated the effect of the condition of lubrication on the friction between brackets and NiTi archwires of different rounded cross-sections.
Methods:
Brackets (Roth, GAC) were affixed to a device connected to a universal testing machine into which segments of archwire were placed (NiTi, Nitinol, GAC) with cross-sections of 0.012-in, 0.016-in and 0.020-in. Once the wire was in the bracket slot, the following lubricants were applied: human saliva (HS: positive control), distilled water (DI), mucin-based (MUC) or carboxymethylcellulose-based (CMC) artificial saliva. In the negative control group, no lubricant was used. The combination between the wire cross-sections and the lubrication condition generated 15 groups with 15 samples each. Data were submitted to two-way analysis of variance and Tukey's test.
Results:
There was no significant interaction between the wire cross-section and the condition of lubrication (p= 0.901). Irrespective of whether lubricants were used or not, there was a significant increase in friction with an increase in the cross-section of the wire (p< 0.001). For any wire, the group tested in the presence of MUC was not different from that in which HS was applied. On the other hand, when the application of lubricants was suppressed, significantly higher friction values were observed. The CMC group and the DI group demonstrated intermediate behavior.
Conclusions:
Friction increased with the increase of the cross-section of the NiTi archwire, but regardless of the archwire, friction with MUC artificial saliva was similar to that of HS and lower than in dry conditions.
Related Concept Videos
Cross-Sectional Research
Profile Leveling and Cross Sections
Spinal Cord: Cross-sectional Anatomy
Gray Matter and its Components
Central to the gray matter is...
Kinetic Friction
Types of Friction Problems
The first type of dry friction problem involves situations where there is no apparent impending motion....
Friction: Problem Solving
Initially, a visual representation of the...