Related Experiment Video
Updated: Jan 24, 2026

Operating Procedures of the Electrochemotherapy for Treatment of Tumor in Dogs and Cats
Published on: October 24, 2016
Electrochemotherapy of superficial tumors - Current status:: Basic principles, operating procedures, shared
Luca G Campana1, Damijan Miklavčič2, Giulia Bertino3
1Department of Surgery Oncology and Gastroenterology (DISCOG), University of Padua, Italy; Surgical Oncology, Veneto Institute of Oncology IOV-IRCCS, Padua, Italy.
Abstract:
Treatment of superficial tumors with electrochemotherapy (ECT) has shown a steep rise over the past decade and indications range from skin cancers to locally advanced or metastatic neoplasms. Based on reversible electroporation, which is a physical method to achieve transient tumor cell membrane permeabilization by means of short electric pulses, ECT increases cellular uptake of bleomycin and cisplatin and their cytotoxicity by 8,000- and 80-fold, respectively. Standard operating procedures were established in 2006 and updated in 2018. Ease of administration, patient tolerability, efficacy across histotypes, and repeatability are peculiar advantages, which make standard ECT (ie, ECT using fixed-geometry electrodes) a reliable option for controlling superficial tumor growth locally and preventing their morbidity. Consolidated indications include superficial metastatic melanoma, breast cancer, head and neck skin tumors, nonmelanoma skin cancers, and Kaposi sarcoma. In well-selected patients with oropharyngeal cancers, ECT ensures appreciable symptom control. Emerging applications include skin metastases from visceral or hematological malignancies, vulvar cancer, and some noncancerous skin lesions (keloids and capillary vascular malformations). Repeatability and integration with other oncologic therapies allow for consolidation of response and sustained tumor control. In this review, we present the basic principles of ECT, recently updated operating procedures, anesthesiological management, and provide a synthesis of the efficacy of standard ECT across histotypes.
Related Concept Videos
Basic Operations on Signals
Time Reversal mirrors a continuous-time signal about the vertical axis at t=0. This is achieved by substituting t with −t. For example, if a signal x(t) is considered, the time-reversed signal is x(−t). This operation can be graphically represented, showing the mirrored signal.
Bernoulli's Principle: Applications
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
Design Example: Application of Archimedes' Principle
The volume of seawater displaced by the block is determined by first calculating the block's weight. This is done by multiplying the...
Indicators
Applications of GIS: Disaster Management and Emergency Response
Emerging Adulthood