Related Experiment Video
Updated: Jan 24, 2026

Longitudinal Evaluation of Mouse Hind Limb Bone Loss After Spinal Cord Injury using Novel, in vivo, Methodology
Published on: December 7, 2011
Marginal Bone Loss Around One-Piece Implants: A 10-Year Radiological and Clinical Follow-up Evaluation
Mahdi Kadkhodazadeh1, Yaser Safi2, Amir Moeintaghavi3
1Professor, Department of Periodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Purpose:
This study was conducted to investigate one-piece narrow-diameter implants installed in maxillary lateral and mandibular incisor sites using immediate nonfunctional loading.
Materials And Methods:
In this 10-year clinical trial study, 42 narrow-diameter (3.0-mm) one-piece implants for 35 patients were inserted. Clinical and radiographic measurements were recorded in 10 years and analyzed statistically using t test.
Results:
A total of 26 patients (20 females and 6 males) with 30 implants were available for the 10-year follow-up. The 10-year implant survival rate was 100%. A statistically significant mean marginal bone loss was observed between 12 months and 10 years (0.18 ± 0.29 mm). The mean pocket depth increase was statistically significant (0.68 ± 0.83 mm). No bleeding on probing was observed around 90% of the implants. Full-mouth plaque index was registered at 20% of the implants.
Conclusion:
The results obtained in this analysis suggest that modest marginal bone loss was observed around the implants. One-piece narrow-diameter implants (Maximus 3.0; BioHorizons) can predictably restore missing maxillary lateral incisors and mandibular incisors in cases of careful patient selection.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
06:53Modeling Primary Bone Tumors and Bone Metastasis with Solid Tumor Graft Implantation into Bone
Published on: September 9, 2020
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Radiological Investigation I: X-ray and CT
Margin of Error
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are: