Related Experiment Video
Updated: Jan 24, 2026

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Transmural unipolar electrogram change occurs within 7 s at the left atrial posterior wall during pulmonary vein
David R Tomlinson1, Madison Myles2, Kara N Stevens3
1South West Cardiothoracic Centre, University Hospitals Plymouth NHS Trust, Plymouth, UK.
Background:
To assess occurrence of a histologically validated measure of transmural (TM) atrial ablation-pure R unipolar electrogram (UE) morphology change-at first-ablated left atrial posterior wall (LAPW) sites during contact force (CF)-guided pulmonary vein isolation (PVI).
Methods:
Objectively annotated VISITAG™ Module and CARTOREPLAY™ (Biosense Webster Inc., Diamond Bar, CA, USA) UE morphology data were retrospectively analyzed in 23 consecutive patients undergoing PVI under general anesthesia.
Results:
PVI without spontaneous/dormant recovery was achieved in all, employing 16.3 (3.2) min of radiofrequency (RF; 30 W) energy. All first-ablated LAPW sites demonstrated RS UE morphology preablation, with RF-induced pure R UE morphology change in 98%. Time to pure R UE morphology was significantly shorter at left-sided LAPW sites (4.9 [2.1] vs 6.7 [2.5] s; P = .02), with significantly greater impedance drop (median 13.5 vs 9.9 Ω; P = .003). Importantly, neither first-site RF duration (14.9 vs 15.0 s) nor maximum ablation catheter tip distance moved (during RF) was significantly different, yet the mean CF was significantly higher at right-sided sites (16.5 vs 11.2 g; P = .002). Concurrent impedance and objectively annotated bipolar electrogram (BE) data demonstrated ∼6-8 Ω impedance drop and ∼30% BE decrease at the time of first pure R UE morphology change.
Conclusions:
Using objective ablation site annotation, UE morphology evidence of TM RF effect was demonstrated far sooner than considered biologically possible according to the "conventional" 20-40 s RF per-site approach, with significantly greater ablative effect evident at left-sided sites. This novel methodology represents a scientifically more rigorous foundation toward future research into the biological effects of RF ablation in vivo.
More Related Videos
Related Concept Videos
Regulation of Expression Occurs at Multiple Steps
Transcription results in the generation of precursor (pre-mRNA) that consists of both exons and introns, which needs further processing before being translated to a...
Regulation of Expression Occurs at Multiple Steps
Global Climate Change
Plant Cell Wall
Standard Entropy Change for a Reaction
Errors occurring during blood pressure monitoring
Several factors...