Related Experiment Video
Updated: Jan 24, 2026

Using a Virtual Store As a Research Tool to Investigate Consumer In-store Behavior
Published on: July 24, 2017
A REVIEW ON 210Po AND 210Pb IN INDIAN SEAFOOD AND DOSE TO CONSUMERS
G Sankaran Pillai1, S Chandrasekaran1, R Baskaran1
1Radiological, Environment and Safety Division (RESD), Health Safety and Environment Group (HSEG), Indira Gandhi Centre for Atomic Research, Homi Bhabha National Institute (HBNI), Kalpakkam 603 102, Tamil Nadu, India.
Abstract:
India is the second largest seafood producer in the world marketing more than 7000 edible species. In this regard, commendable studies have been conducted since the 1970s by different research groups and more data are reported. In this work, all the studies on 210Po and 210Pb measurements in abiotic and biotic components of India have been combined and reviewed. The concentrations of 210Po and 210Pb are estimated by radiochemical separation followed by alpha counting. Grain size, season, Tsunami waves and place of sampling have a decisive bearing on 210Po and 210Pb concentration in abiotic components. Plankton shows a higher Kd factor (104) compared to seaweeds and sea grass (103). Pond ecosystems recorded the highest Kd factor (4·3 × 104) compared to other freshwater and marine ecosystems. Bioaccumulation of 210Po and 210Pb varies with respect to variety of seafood. The committed effective dose (CED) calculated for shellfish species maintained a higher range of 2.5 × 10-2 mSv/y to 9.8 × 10-1 mSv/y and for fish species fluctuated from 3.8 × 10-4 mSv/y to 2.0 × 10-1 mSv/y. The studies conducted so far are scattered, and need to be gathered for future reference and planning (i.e. There is not much information available for Kerala, Karnataka, Maharashtra, Gujarat, Andhra, West Bengal and Odessa coast). Therefore, it is strongly recommended that further and more complete research is undertaken to study the bioaccumulation of 210Po and 210Pb from seafood. Overall, the present review concludes that Indian seafood is radiologically safe.
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dose-Response Relationship: Overview

