Precision Parameters for the FDA Shellfish Laboratory Quality Assurance Program for 1973-1989

James T Peeler1, Thomas E Graham2, Larry J Maturin2

  • 1Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Washington, DC 20204.

Insights

This study evaluated the precision of four microbiological methods used in the U.S. Food and Drug Administration

Area of Science:

  • Microbiology
  • Food Safety
  • Analytical Chemistry

Background:

  • Microbiological testing is crucial for ensuring shellfish safety.
  • The U.S. Food and Drug Administration (FDA) relies on specific analytical methods for its Shellfish Quality Assurance Program.
  • Understanding the precision of these methods is essential for reliable quality assessment.

Purpose of the Study:

  • To compute and analyze the precision parameters of key microbiological methods.
  • To provide data on the reproducibility of these methods over an extended period.
  • To support the ongoing quality assurance of shellfish.

Main Methods:

  • Calculation of pooled reproducibility variance (SR2).
  • Analysis of data from four distinct microbiological methods: coliform most probable number (MPN), fecal coliform MPN, Staphylococcus aureus plate count, and standard plate count.
  • Utilized historical data from the FDA's Shellfish Quality Assurance Program (1973-1989).

Main Results:

  • The pooled reproducibility variances (SR2) were determined for each method.
  • Variances ranged from 0.0087 for standard plate count to 0.1181 for fecal coliform MPN.
  • These values quantify the variability inherent in each analytical technique.

Conclusions:

  • The study provides essential precision data for commonly used shellfish microbiological analysis methods.
  • The calculated variances offer insights into the reliability and consistency of these methods.
  • This information is vital for maintaining and improving shellfish safety standards through the FDA's program.

Related Concept Videos

Quality Assurance01:19

Quality Assurance

Quality assurance is the overarching term used to describe the activities employed to ensure the proper performance of a system. These activities can be classified into three categories: quality control, quality assessment, and internal corrective measures. Typically, these activities work cyclically: quality control is performed before and during the analysis, while quality assessment occurs during and after the investigation. Internal corrective measures are implemented based on the findings...
1.1K
FDA Approved Drugs: Changes to Approved Drugs01:26

FDA Approved Drugs: Changes to Approved Drugs

Post-approval, manufacturers may modify an approved new or generic drug product. Such modifications can encompass alterations in the Active Pharmaceutical Ingredient (API), manufacturing process, formulation, batch size, manufacturing site, and container closure system (FDA Guidance for Industry, April 2004). Often, a drug product may undergo multiple changes.These modifications require careful evaluation to determine their potential impact on the drug product's identity, strength, quality,...
248
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
100.5K
Wave Parameters01:10

Wave Parameters

The simplest mechanical waves are associated with simple harmonic motion and repeat themselves for several cycles. These simple harmonic waves can be modeled using a combination of sine and cosine functions. Consider a simplified surface water wave that moves across the water's surface. Unlike complex ocean waves, in surface water waves, water moves vertically, oscillating up and down, whereas the disturbance of the wave moves horizontally through the medium. If a seagull is floating on the...
9.1K
Quality of Water01:19

Quality of Water

In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
514
Quality Control01:05

Quality Control

Quality control is one of the three cyclical quality assurance activities that help keep a system under statistical control. Typical quality control activities include creating quality control charts, conducting proficiency testing, and documenting and archiving results.
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
1.4K